iec 60068 part 2 64 pdf

by iec 60068 part 2 64 pdf

Standardization in Electric Vehicles

iec 60068 part 2 64 pdf

Standardization in Electric Vehicles

Standardization in Electric Vehicles

On-board storage Built-in Micro SD/SDXC slot, up to 64 GB General Operating Conditions-30 °C – 60 °C (-22 °F – 140 °F) Humidity 95% or less (non-condensing) Power Supply 12 VDC ± 10% / PoE (802.3af) Power Consumption Max. 12W IR range Max. 15m Protection IEC 60068-2 … CE, IEC 62109-1/2, IEC 61727, IEC 62116, VDE 0126-1-1, Greece, VFR 2014, CEI 0-21, CEI 0-16, VDE-AR-N4105, EN50438, G99/3, AS 4777, PEA, IEC 60529, IEC 60068, IEC 61683, DRRG 230V/400V 50/60Hz, ±5Hz 50/60Hz, ±5Hz 50/60Hz, ±5Hz 50/60Hz, ±5Hz 230V/400V 230V/400V 277V/480V Ficha de dados Número de MPPT independentes / strings por TMPP CE, IEC 62109-1/2, IEC 61727, IEC 62116, VDE 0126-1-1, Greece, VFR 2014, CEI 0-21, CEI 0-16, VDE-AR-N4105, EN50438, G59/3, AS 4777, PEA, IEC 60529, IEC 60068, IEC 61683, DRRG Rated AC output power Max. AC apparent power Max. output current AC nominal voltage AC grid frequency Power factor THDi AC grid connection type Max.efficiency Euro - eta 1000000 ciclos, AC-15, 2 A a 230 V, taxa de produção 3600 cic/h, factor de carga: 0,5em conformidade com EN / IEC 60947-5-1 APÊNDICE C 1000000 ciclos, AC-15, 3 A a 120 V, taxa de produção 3600 cic/h, factor de carga: 0,5em conformidade com EN / IEC 60947-5-1 APÊNDICE C 1000000 ciclos, AC-15, 4 A a 24 V, taxa de produção 3600 cic/h, factor de carga: 0,5em conformidade com EN / IEC 60947 ... 5 gn (f= 12…500 Hz)em conformidade com IEC 60068-2-6 resistência ao choque 30 gn (duração = 18 ms) para aceleração em meia onda sinusoidalem conformidade com IEC 60068-2-27 Certificado de Acreditação - Grupo ISQ AUTOMAÇÃO, PROTEÇÃO, COMANDO, CONTROLO E … NORMA ORIGEM CONDENSAÇÃO E HUMIDADE NEVOEIRO … EMI 55 A / AY

INSTALAÇÕES AT E MT. SUBESTAÇÕES DE DISTRIBUIÇÃO

INSTALAÇÕES AT E MT. SUBESTAÇÕES DE DISTRIBUIÇÃO

IEC 61000-6-2 IEC 61000-6-4 MECHANICAL SPECIFICATIONS Shaft diameter ø 6 / 9,52 (3/8”) / 10 mm Enclosure rating X = IP 54 (IEC 60529) S = IP 66 (IEC 60529) Max rotation speed 3000 rpm (IP 66) 6000 rpm (IP 54) Max shaft load 10 N axial / 20 N radial with ø6 shaft 100 N axial / radial Shock 50 G, 11 ms (IEC 60068-2-27) Ficha técnica O2V100 - Dados técnicos, acessórios, instruções de uso, CAD e possibilidades de encomenda, assim como outras informações e aplicações sobre o artigo procurado. 4/64 SM 1231 analog input module 4/67 SM 1232 analog output module ... test acc. to / tested with IEC 68, Part 2-27/half-sine: magnitude of shock 15 g (peak value), duration 11 ms, ... (EN 60068-2-52) Mechanically active substances EN60721-3-3 3S4 • Dust (suspended substance content)

CONTADORES DE ENERGIA ELÉTRICA

CONTADORES DE ENERGIA ELÉTRICA

estándar IEC 60068-2-32 Descarga electrostática: +/- 15 kV (aire), +/- 8 kV (directa) Arquitectura del sistema y características de rendimiento Procesador multinúcleo a 1 GHz de Texas Instruments Sistema operativo Microsoft® Windows Embedded Handheld 6.5.3 y navegador HTML5 de Intermec IEC 60479-1. Contact with live part Direct contact. Do you need a multi-user copy? The fault current raises the exposed-conductive-part to a voltage liable to be hazardous as it generates a touch current through a person coming into iiec with this exposed-conductive-part see Fig. Contents 1 – Introduction 1. IEC 60169-1 PDF - IEC /AMD Standard | Amendment 1 - Radio-frequency connectors - Part 1: General requirements and measuring. IEC /AMD Standard | Amendment 1 -

INSTALAÇÕES AT E MT. SUBESTAÇÕES DE DISTRIBUIÇÃO

INSTALAÇÕES AT E MT. SUBESTAÇÕES DE DISTRIBUIÇÃO

IEC 60335-2-64 NP EN 60335-2-64 0 16 Aparelhos Elétricos para Aquários e Lagos de Jardins Electrical Appliances for Use with Aquariums and Garden Ponds Segurança Elétrica Electrical Safety EN 60335-2-55 IEC 60335-2-55 NP EN 60335-2-55 0 . PORTUGUESE ACCREDITATION INSTITUTE Edição Titulo . IED 60044-1 : 2003 Instrumental transformers Part 1: Current transformers – IEC 60068-2-1 (*) 2007 Environmental testing – Part 2-1: Tests – Test A: Cold BS 5466 Part 2 UK BS 5466 Part 3 UK BS 7479 UK BS EN ISO 7253 UK BS EN 60068-2-11 UK BS EN 60068-2-52 UK D17 1058 ... IEC 60068-2-52 Europe ISO 3231 Europe ISO 3768 Europe ISO 3769 Europe ISO 3770 Europe ... tabela normas.PDF

FICHA TÉCNICA DO PRODUTO LS PFM -1500/865/5/IP66

FICHA TÉCNICA DO PRODUTO LS PFM -1500/865/5/IP66

Enclosure rating X = IP 64 (IEC 60529) S = IP 67 (IEC 60529) Max rotation speed 10000 rpm Shock 50 G, 11 ms (IEC 60068-2-27) Vibration 10 G, 10 ... 2000 Hz (IEC 60068-2-6) Moment of inertia (magnet actuator) 0,1 x 10-6 kgm2 Body material EN-AW 2011 aluminum Housing material painted aluminum Magnet-actuator material 10 g (IEC 60068-2-27, vibration under resonance) Shock resistance 50 g (per IEC 60068-2-6, ... SP2 Switching output 2 Materials Wetted parts Process connection:Stainless steel 1.4435 / 316L Non-wetted parts Case: Stainless steel 304 ... 2" 40 56.6 64 1) ... IEC 60068-2-30:2005 Environmental testing – Part 2-30: Tests – Test Db: Damp heat, cyclic (12h + 12h cycle) IEC 61683:1999 Photovoltaic systems – Power conditioners – Procedu re for measuring Use only factory-authorized replacement parts and procedures. WARNING, CAUTION, and NOTE WARNING A WARNING provides information which, if disregarded, could result in injury or death. ... IEC 60068-1, IEC 60068-2, IEC 60068-3, and IEC 60068-5 Dimensions (mm) ..... IEC 61215, IEC 61730, IEC TS 62804, IEC 61701, IEC 62716, IEC 60068-2-68 ISO 9001: 2015 Quality management systems ISO 14001: 2015 Environmental management systems OHSAS 18001: 2007 Occupational health and safety manage-ment systems IEC TS 62941: 2016 Terrestrial photovoltaic (PV) modules – Guidelines for increased confidence in PV module design Vibration resistance EN 60068-2-6, EN 60068-2-64 Shock resistance EN 60068-2-27 Classifications [email protected] 5.0 27270801 [email protected] 5.1.4 27270801 [email protected] 6.0 27270801 [email protected] 6.2 27270801 [email protected] 7.0 27270801 [email protected] 8.0 27270801 [email protected] 8.1 27270801 2018-05-27 02:46:13 | Online data sheet Subject to change without notice DISTANCE SENSORS | SICK 3 Dx50 DT50-P1123, Online data sheetLightning Protection according to IEC 62305DS-2CD6362F-I(S)(V)NP ISO/IEC 17025 BY IPAC international committee of IEC, translated in the standard IEC 62305 – Lightning Protection, and apply it to a computer program. In order to accomplish that, it is crucial to dominate two subjects: (1) the characterization of the Armazenamento int.Slot Micro SD/SDXC, até 64 GB Geral Condições operação-30 °C – 60 °C Humidade 95% ou menos (sem condensação) Alimentação 12 VDC ± 10% / PoE (802.3af) Consumo Max. 12WJunction bo Alcance IV Max. 15m Proteção Teste IEC 60068-2-75 , Eh, 50J; EN 50102, EN50155, IK10 Dimensões 164 x 152.8 x 43.8mm Peso 1400g 6 ... Climatic: EN 60068-2-30 / 38 / 78 Corrosion: EN 60068-2-11 / 42 / 52 / 60 | EN ISO 9227 Mechanical: EN 60068-2-6 / 27 / 31 / 64 / 75 IP: EN 60529 | ISO 20653 Weathering: EN 60068-2-5/9 | DIN 75220 Ozone: ISO 1431-1 | EN 60811-403 Conducted transient immunity UN ECE R10 Rev. 4 and Rev. 5 ISO 7637-2 -Transients on Supply Lines ISO 7637-3 ... instalações elétricas de baixa tensão pdf el arte moderno giulio carlo argan pdf 64 mm. profundidade: 30 mm. Ambiente; ... 50 gn para 11 msem conformidade com IEC 60068-2-27. resistência à vibração: 25 gn (f= 10…500 Hz)em conformidade com IEC 60068-2-6. classe de protecção contra choques eléctricos: Classe Iem conformidade com IEC 61140 ... prp.document.label.format pdf. Dimensões 237.4 KB. Data 15-03-2018 ... Eye safety IEC 60825-1 Housing IEC 60529, IP65 (optical head), IP64 (processing unit) Shocks & vibrations IEC 60068-2 EMC & Lightning IEC 61326-1, IEC 62311, IEC 61000-4, FCC part 15 Electrical safety IEC 61010-1 Other tests completed Wind tunnel test, cold temperatures, snow, freezing rain Wind measurements made profitable IEC 60068-2-1 and IEC 60068-2-2 Damp heat 40 °C at 95 % rel. humidity in line with IEC 60068-2-30 Mechanical resistance vibration test, sinusoidal 5 Hz to 150 Hz in line with IEC 60068-2-6 vibration test, random 10 Hz to 300 Hz in line with IEC 60068-2-64 shock test 40 g shock spectrum in line with IEC 60068-2-27, MIL-STD-810 ... Vibration Protection Operating, IEC 60068-2-64, 1Grms, random, 5 ~ 500Hz,1 hr/axis. Advantages The computer uses the iDoor technology that provides diverse system IO, Fieldbus Protocol support and 3G/GPS/GPRS/Wi-Fi communication, allowing to expand the computer capabilities and functionalities in a modular and easy way for the end customer. Tropicalized as per DIN IEC 68 Part 2-38: Degree of protection: IP 66: Shock resistance: DIN EN 60068-2-27/IEC 68-2-27: 30g: Vibration resistance: DIN EN 60068-2-64/IEC 68-2-64: 20 to 2000 Hz, 1 (m/s²)² /Hz (with min. rod length 150 mm) EMC: Interference emission to EN 61326, electrical equipment class B; Interference immunity to EN 61326 ... exceeded the standard’s factor of 2.5, with the most amplification seen in the X axis (direction of the switch with lower stiffness, perpendicular to the switch base). The latter amplification is more than two times greater than the 2.5 factor with the largest amplification is as high as 5.5 10 0 10 1 0 2 4 6 8 10 12 Frequency, Hz Spectral ... Accelerations up to 2 g at frequency up to 1000 Hz (according to IEC 60068–2–6) Shock resistance Acceleration: 50 g Duration: 11 ms (according to IEC 60068–2–27) Wet and dust-laden atmospheres The transmitter is dust and sand tight and protected against immersion effects as defined by IEC 60529 (2001) to IP67 (IP 68 on request) or by ... VALSTEAM ADCA We reserve the right to change the design and material of this product without notice. IS PCS1.10 E 06.17 FS= Full Scale. 1) Including Non-linearity, Hysteresis, Repeatability, Zero-offset and Span-offset (acc. to IEC 61298-2). Accelerations up to 2 g at frequency up to 1000 Hz (according to IEC 60068–2–6) Shock resistance Acceleration: 50 g Duration: 11 ms (according to IEC 60068–2–27) Wet and dust-laden atmospheres The transmitter is dust and sand tight and protected against immersion effects as … IEC 60068-1 Environmental testing - Part 1: General and guidance (sixth edition 1988 + A1:1992). IEC 60068-2 Basic environmental testing procedures: Part 2 Tests : 60068-2-1 Tests A: Cold. (Fifth edition 1990, including amendments A1: 1993 & A2: 1994); 60068-2-2 Tests B: Dry heat. Desenho dimensional Ligação eléctrica 3D PDF Ficha técnica em PDF Para o ... DIN IEC 60068-2-27 / DIN IEC 60068-2-29: 1000 g: ... Resistência a vibrações: DIN IEC 68-2-6: 20 g (10...2000 Hz) DIN EN 60068-2-64: 14 g: DIN EN 61373: Categoria 2: MTTF [anos] 310: Diretiva de equipamentos sob pressão: Boas práticas de engenharia; pode ser ... Schneider Electric Portugal. XCKM102 - limit switch XCKM - steel roller plunger - 1NC+1NO - snap action - Pg11 Em quase todas as indústrias são cada vez mais exigidos computadores robustos e de alta performance como componentes das máquinas. Estes são muitas vezes o “cérebro” do sistema ou atuam como interface para o controlo da máquina pelo trabalhador. O UNO-1372G da Advantech é um computador com CPU Intel Atom Quad-Core e montagem em calha DIN. Este computador é caracterizado pela … IEC 61000-6-2 IEC 61000-6-3 MECHANICAL SPECIFICATIONS Bore diameter (magnet-actuator) ø 6 / 8 / 9,52 (3/8”) / 10 mm Enclosure rating IP 67 (IEC 60529) Max rotation speed 10000 rpm Shock 50 G, 11 ms (IEC 60068-2-27) Vibration 10 G, 10 ... 2000 Hz (IEC 60068-2-6) Moment of inertia (magnet-actuator) 0,1 x 10-6 kgm2 Body material EN-AW 2011 aluminum IEC 62109-1/2, IEC 61727, IEC 62116, VDE 0126-1-1, VFR 2014, CEI 0-21, CEI 0-16, VDE-AR-N4105, EN50438, G99/3, AS 4777, PEA, IEC 60529, IEC 60068, IEC 61683, IEC61000-6/3 230V/400V 50/60Hz, ±5Hz 50/60Hz, ±5Hz 50/60Hz, ±5Hz 50/60Hz, ±5Hz 230V/400V 230V/400V 277V/480V Ficha de dados Número de MPPT independentes / strings por MPPT Electronic pressure switch with display For sanitary ...Equipment: PV Grid inverter Test Model No.: Growatt ...1ZSC000857-AAB en, Rev. 2, 2006-06-15 Type TEC ...290W Half-Cell Module Poly JAP60S03 270-290/SC Ficha técnica PP002E - Dados técnicos, acessórios, instruções de uso, CAD e possibilidades de encomenda, assim como outras informações e aplicações sobre o artigo procurado.

Leave a Comment:
Andry
PCB terminal block, nominal current: 15 A, rated voltage (III/2): 400 V, nominal cross section: 1.5 mm², pitch: 5.08 mm, number of positions: 11, connection method ...
Saha
Climatic category (IEC 60068-1): 55/100/56 Construction Dielectric: polypropylene (PP) Wound capacitor technology with internal series connection Plastic case (UL 94 V-0) Epoxy resin sealing (UL 94 V-0) Features High pulse strength and high contact reliability Very low inductance RoHS-compatible Terminals XALD222 - estação de controlo XAL-D – duas funções ...
Marikson
5 gn (f= 12…500 Hz)em conformidade com IEC 60068-2-6 resistência ao choque 30 gn (duração = 18 ms) para aceleração em meia onda sinusoidalem conformidade com IEC 60068-2-27 IEC 60815 Guide for the Selection of Insulators in Respect of Polluted Conditions IEC 60068-2-5 Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing IEC 61869-1 Instrument transformers - Part 1: General requirements 3.1.3 Electrical Ratings XALD222E - estação de controlo XAL-D – duas funções ...
Search
Test Requirements for Seismic Qualification of Substation ...